2. In the Content pane, select the Disk Drive tab.
3. Click Group to initiate the process for adding the disk to a disk group.
NOTE:
If the Device Addition Policy is set to automatic, the disk will automatically be added to a disk group. In
this case the Group option will not be available.
Returning the failed component
Please follow the return instructions provided with the new component.
Replacing the disk enclosure p ower supply/blower
This section describes the procedure for replacing the power supply/blower assembly used in EVA
4000/6000/8000 products.
NOTE:
Because this component is used in sever al products, the drawings may reect a different enclosur e than
the one you have. The removal and replacement procedure is the same for each product.
Before you begin
Observe the following precautions when replacing the power supply/blower.
CAUTION:
You have only seven minutes to perform the replacement procedure! Both power supplies must b e
installed for the enclosure to cool properly. If a power supply fails, leave it in place in the enclosure until
a new power supply is available to install. The enclosure could shut down due to overheating unless the
power supply is replaced within seven minutes of removal of the failed/failing power supply.
If cabling is obstructing access to the power supply/blower, carefully move the cables out of the way
to avoid loosening any connections.
Parts can be da maged by electrostatic discharge. Use proper anti-static protection. Refer to the
documentation that shipped with your system for additional i nformation.
Have a copy of the product User Guide available for reference. You can download a copy of the User
Guide from the product s upport page on the HP web site.
Verifying component failure
CAUTION:
If Command View E VA does not present a status consistent with that of the power supply/blower status
indicator, or if Command View or the System Event Analyzer indicates multiple hardware failures,
contact HP support for assistance. The HP support web site is located at h
ttp://www.hp.com/support
The p ower supply and blower are separately replaceable com ponents. Before replacing a power supply
or blower, use the following methods to verify the component failure:
Analyze any failure messages you may have received from system mon itoring (System Event
Analyzer).
Check status using Command View EVA:
Enterprise Virtual Array 3000/5000 user guide