5. Click Save changes
Installing a disk drive
1. Push in the eje
ctor push button on the disk d rive and pull the release lever down to the full open
position.
2. Insertthedriveintotheenclosureasfarasitwillgo(1,Figure 34).
3. Close the rele
ase lever until it engag es the ejector push but ton, and the disk drive seats in the
backplane (2).
4. Press in firmly on the disk drive to ensure it is seated properly.
1
1
2
0116a
Figu re 34 Inst alling a disk drive
V erify ing proper operation
After replacing the disk drive, check the following to verify that the disk drive is operating normally:
NOTE:
It may take up to 10 minutes for the component to display good status.
• Check the disk drive status indicators. See Figure 32.
•Activityindicator(1)shouldbeonorflashing
• Online indicator (2) should be on or flashing
• Fault indicator (3) should be off
• Check the following using Command View EVA.
• Navigate b ack to the component and check the operational state. It should be
.
•RecordtheModel number and the Firmware version.Checkthefirmware version against the
supported disk firmware in the HP StorageWorks Enterprise Virtual Array release notes.The
most current edition of the release notes can be downloaded from the following web site:
h
ttp://www.hp.com/go/eva5000
Click Technical docum entatio n.
If the disk d rive is using an unsupported version of firmware, download the correct firmware
from the following web site and install it using the instructions included with the firmware file.
Use the disk drive model number to locate the correct firmware file. Do not add the d isk drive
to a disk group if it using an unsupported firmware version.
h
ttp://www.hp.com/support/evadiskfirmware
Adding a disk to a disk group
After replacing the disk, it s hould b e added to a disk group. The disk is typically added back into
its original disk group.
1. In the Navigation pane, select Storage system > Hardware > Rac k > Disk enclosure > B ay
90
Customer replaceable units