Manual
Replacing the fa
iled component
CAUTION:
Components can be dam aged by electrostatic discharge. Observe the following proper anti-static
protection:
• Always transpo
rt and store CRUs in an ESD protective enclosure.
• Do not remove the CRU from the ESD protective enclosure until you are ready to install it.
• Always use ESD precautions, such as a wrist strap, heel straps on conductive flooring, and an ESD
protective sm
ock when handling ESD sensitive equipment.
• Avoid touching the CRU connector pins, leads, or circuitry.
• Do not place ESD generating material such as paper or non anti-static (pink) plastic in an ESD
protective e
nclosure with ESD sensitive equipment.
• HP recommends waiting until periods of low storage system activity to replace a component.
• When replacing components at the rear of the rack, cabling may o bstruct ac cess to the
component. Carefully move any cables out of the way to avoid loosening any connections. In
particular, avoid cable damage that m ay be caused by:
• Kinking or bending.
• Disconnecting cables without capping. If uncapped, cable per formance may be impaired by
contact with dust, metal or other sur faces.
• Placing removed cables on the floor or other surfaces, where they may be walked on or
otherwise compressed.
• Replacement procedures are provided with each component. You can also download the
replacement instructions in Dutch, English, French, German, Italian, Spanish and Japanese from
the following web sites:
• h
ttp://www.hp.com/go/eva4000
• http://ww w.hp.com/go/eva6000
• http://ww w.hp.com/go/eva8000
From any of these web sites, select Technical documents und er Product information for additional
information.
Returning the defective part
• HP specifies, in the materials shipped with a replacement CSR part, whether the defective
component must be returned to HP. Where required, you must ship the defective c omponent back
to HP within a definedperiodoftime,normallyfive (5) business days. The defective comp onent
must be returned with the associated documentation provided in the shipping material. Failure
to return the defective comp onent may result in HP billing you for the replacement. With a
customer self repair, HP will pay all shipping and component return costs and determine the
courier/carrier to be used.
Replacing a disk drive
This section describes the procedure for replacing a Fibre Channel disk drive.
Before you begin
Observe the following precautions when replacing the disk drive.
Enterprise Virtual Array 3000/5000 user guide
87