Manual
4. Press a nd release the bottom push button to accept the change and to display Au. The bottom push
button indicator is now off.
Muting or unmut
ing the audible alarm
You may want to m
ute the alarm in the following situations:
• The error does not require immediate c orrective action.
• You c anno t correct the error at this time. For example, the error may require a replacement part.
To mute the aud
ible alarm:
NOTE:
Er
isdisplayedinthealphanumericdisplaywhenanerrorconditionispresent.
1. Press and hold the bottom push button until the status indicator is On.
A muted alarm will remain off until a new condition report exists.
2. To unmute the alarm, press and hold the bottom push button until the status indicator is Off.Whena
new error condition occurs, the alarm will sound.
Disabling the audible alarm
CAUTION:
Disabling the audible alarm increases the potential of damage to equipment from a reported but
unobserved fault. HP does not recommend disabling the audible alarm.
Disabling the audible alarm affects only one enclosure. This action does not affect condition report
displays on
the EMU alphanumeric display or errors reported by HP Command View EVA.
To disable the alarm:
1. Press and release the bottom push button until the alphanumeric display is Au.
2. Press and h
oldthetoppushbuttonuntilthealphanumericdisplayisaFlashingon (Audible Alarm
On).
NOTE:
When the alarm display is flashing, pressing and holding the top push button causes
the display to rapidly change between
on
and
oF
and also causes the display to select
the next st
ate.
3. Press and release the top push button to change the display to a Flashing oF (Audible Alarm Off).
4. Press and release the bottom p ush button to accept the change and display Au. The bottom push
button indicator is now on.
NOTE:
Adisabledaudible alarm (the bottom push button indicator is on) cannot sound for any
error c ondition. To ensure that you are immediately alerted to error conditions, it is
r ecommended that the alarm mute function be used rather than the alarm disable function.
If you must use the disable function, remember to enable the audible alarm as soon as
possible to ensure that you are alerted to errors.
Enterprise Virtual Array 3000/5000 user guide
57