Table 10 O perational disk drive status indica tions
Activity
Online Fault
Description
Flashing
On
Off
Initial startup.
On On
Off
The drive is online but is not being accessed.
Flashing Flashing Flashing The drive is being located.
Flashing
On
Off
The drive is operational and active.
Table 11 Non-ope rational disk drive status indications
Activity
Online Fault
Description
On On On
Indicates no connection or the controllers are ofine.
Recommended corrective actions:
1. Check power supplies for proper operation.
2. If defective, replace disk drive.
On
Off
Flashing
Indicates disk drive error/not active. Recommended
corrective actions:
1. Verify FC loop continuity.
2. Replace disk drive.
Disk drive blank
To maintain the proper enclosure air ow, a disk drive or a disk drive b lank must be installed in each
drive bay. The disk drive blank maintains proper a ir ow within the disk enclosure.
Power supplies and blowers
This section describes the function and o peration of the disk enclosure power supplies and blowers.
Figure 16 illustrates the major power supply and cooling components.
CXO7489
A
1
3
4
5
5
6
2
Figure 16 Power supply and blower assembly components
1. Power supply
2. Status indicator
3. AC Input connector with bail
4. Module latch (wine-colored)
5. Blower tabs (wine-colored)
6. Blower
Enterprise Virtual Array 3000/5000 user guide