Manual

8.7.en.01 CRITICAL condition—I/O module unsupported
The I/O module Fibre Channel link speed is not supported by the backplane. This error prevents the
controller fro
m establishing a link with enclosure drives and elim inates the enclosure dual-loop capability.
This condition report remains active until the problem is corrected.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service repres
entative.
8.7.en.02 CRITICAL condition—I/O module communication
The I/O module is u n able to communicate with the EMU.
Complete the following procedure to correct this problem:
1. Record all six characters of the c ondition report.
2. Contact your HP authorized service representative.
IMPORTANT:
Multiple erroneous error messages indicating I2C bus errors, such as NVRAM errors,
blowers m issing, a nd so forth, could indicate an EMU problem.
8.7.en.10 NONCRITICAL condition—I/O module NVRAM read
An invalid NVRAM read occurred and automatic recovery was initiated.
Complete the following procedure to correct this problem:
1. Record all six characters of the c ondition report.
2. Observe the I/O module status indicators for an operational display.
3. Contact your HP authorized service representative.
8.7.en.11 NONCRITICAL condition—I/O module NVR AM write
ThesystemisunabletowritedatatotheI/OmoduleNVRAM.
Complete the following procedure to correct this problem:
1. Record all six characters of the c ondition report.
2. Observe the I/O module status indicators for an operational display.
3. Contact your HP authorized service representative.
8.7.en.12 NONCRITICAL con dition—I/O Mod ule NVRAM read failure
The system is unable to read da ta from the I/O modu le NVRAM.
Complete the following procedure to correct this problem:
1. Record all six characters of the c ondition report.
2. Contact your HP authorized service representative.
8.7.en.13 NONCRITICAL condition—I/O module removed
The system detects that an I/O module has be en removed.
To correct the problem, install an I/O module.
132
EMU-generated condition reports