Instruction Manual
i. Select the Initiator in the left-hand column of the Discovered ISCSI Initiator list.
ii. Click the Information tab.
iii. Select the Enable CHAP check box.
iv. Enter a CHAP secret. For example:
CHAPsecret01
b. To enable CHAP for the mpx100/100b Discovered iSCSI Initiator entry using the
mpx100/100b CLI:
• If the iSCSI Initiator is not listed under the Show Initiators command:
i. Enter the initiator add command and add the iSCSI Initiator that is about to
do discovery.
ii. Enable CHAP and enter a CHAP secret. For example:
CHAPsecret01
• If the iSCSI Initiator is already listed under the Show Initiators command:
i. Enter the initiator mod command and select the iSCSI Initiator that is about to
do discovery.
ii. Enable CHAP and enter a CHAP secret. For example:
CHAPsecret01
2. Enable CHAP for the mpx100/100b iSCSI port:
• To enable CHAP for the mpx100/100b iSCSI port using the HP StorageWorks mpx Manager:
a. Select the appropriate iSCSI port number.
b. Click Advanced Configuration.
c. Select the Enable CHAP check box.
d. Enter a CHAP secret. For example:
hpstorageworks
• To enable CHAP for the mpx100/100b iSCSI port using the mpx100/100b CLI:
a. Enter the set iscsi portnumber command.
b. Select the Presented Target the initiator will log in to.
c. Select the BiDi Discovery CHAP check box.
d. Enter a CHAP secret. For example:
hpstorageworks
3. Enable CHAP on the mpx100/100b iSCSI Presented Target.
a. Click the General tab.
b. Click Secret in the middle of the screen.
c. Click Reset.
d. Enter the mpx100/100b iSCSI Presented Target CHAP secret. For example:
hpstorageworks
e. Click OK.
f. Click Discovery.
• For manually discovering iSCSI target portals:
i. Click Add under Target Portals.
ii. Enter the IP address of the iSCSI port of the mpx100/100b.
EVA iSCSI Connectivity User Guide 217