Instruction Manual
CXO8040
A
Front
Rear
1
2
9
1
0
876 5 43
Figure 44 HSV110 controller—front and rear views
1. Bezel
2. OCP
3. HF1 port
4. HF2 port
5. Mirror port
6. 1B port
7. 2B port
8. 1A port
9. 2A port
10. Power input
High availability features
Two interconnected controllers ensures that the failure of a controller element (such as a power supply,
transceiver, fiber optic or copper Fibre Channel cable, Fibre Channel port, and so forth) does not disable
the syst
em. For EVA5000 configurations, the complete data redundancy configuration includes two
Loop A a
nd two Loop B data paths. For EVA 3000 configurations, data redundancy is accomplished
with two Loop A data paths.
A single c ontroller can fully suppor t an entire system until the defective c ontroller, or controller element,
is repa
ired.
If a blower fails, it can be replaced without shuttin g down the system.
Each HSV110 controller has two lead-acid cache batter y assemblies that provide power to the cache
memory
dual in-line m emory modules (DIMMs). Each battery assembly has three lead-acid, nonspillable
cells. When b oth battery assemblies are fully charged, they can provide power to the DIMMs for up to
96 hours.
Operator control panel
The OCP (see Figure 45)isaninterfacebetweenyouandthecontroller. Muchoftheinformationprovided
here duplicates information displayed on the Command View EVA graphical user interface (GUI). Even if
you cannot observe the GUI, or if the GUI is not functioning, the controller status is available on the OCP.
You c an use the OCP LEDs, the LCD, and the push-buttons to determine the controller status.
The OCP displays system information (status and error conditions) and lets you enter data or isolate
problems.
94