Instruction Manual

Disabling the audible alarm
CAUTION:
Disabling the au
dible alarm increases the potential of damage to equipment from a reported but
unobserved fau
lt. HP does not recommend disabling the audible alarm.
Disabling the audible alarm affects only one enclosure. This action does not affect condition report
displays on the EMU alphanumeric display or the Command View EVA GUI.
To disable the alarm:
1. Press and release the bottom push-button until the alphanumeric display is Au.
2. Press a nd hold the top p ush-button until the alphanumeric display is a Flashing on (Audible Alarm
On).
NOTE:
When the alarm display is ashing, pressing and holding the top push-button causes the
display to rapidly change between on and oF.
Pressing and releasing the top push-button causes the display to select the next state.
3. Press a nd release the top push-button to change the display to a Flashing oF (Audible Alarm Off).
4. Press and release the bottom push-button to accept the change and display Au.Thebottom
push-button LED is now On.
NOTE:
Adisabledaudible alarm (the bot tom push-button LED is On) can not sound for any error
condition. All errors will be d isplayed on the Command View EVA GUI and the EMU
alphanumeric display. HP recommends that rather than disabling the audible alarm,
you use the mute function (see HowtoMuteorUnmutetheAudibleAlarm). When you
use the disable function, you should enable the audible alarm as soon as possible (see
How to Enable the Audible Alarm).
Using the enclosure number feature
This section provides a general description of the purpose, function, and operation of the EMU enclosure
number (En) feature .
En description
In a single rack con guration, the En is a decimal number in the range 00 through 14, which is
automatically assigned by the enclosure address bus.
NOTE:
Your storage system may use an enclosure address bus higher than 14 if your Enterprise supports an
optional expansion cabinet.
By default, the t wo-character alpha numeric display shows this number. Pressing the bottom push-button
changes the display to En,theEndisplaymode.
When the d
isplay is En, pressing and releasing the top push-button displays the enclosure number.
Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)
79