5. Enter CAPTURE CONFIGURATION , specifying the full pa th and lename of the output les for
the conguration data.
The conguration data is stored in a series of from one to ve les, which are SSSU scripts.
The le names begin with the name you choose, with the restore step appended. For example,
if you specify a le name of LargeEVA.txt,theresultantconguration les would be
LargeEVA_Step1A.txt, LargeEVA_Step1B,etc.
The contents of the conguration les can be viewed with a text editor.
NOTE:
If the storage system contains disk drives of different capacities, the SSSU procedures used do not
guarantee that disk drives of the same capacity will be exclusively added to the sam e disk group. If you
need to restore an array conguration that c ontains disks of d ifferent sizes and types, you must manually
r ec reate these disk groups. The controller software and the utility’s CAPTURE CONFIGURATION
command a re not designed to automatically restore this type of con guration. For more information,
refer to the HP StorageWorks Storage System Scripting Utility reference.
The following examples illustrate how to save and restore the storage system conguration data using
SSSU on a Windows host.
Exam ple 1. Savin g conguration data usin g SSSU on a Windows Host
Run SSSU from a DOS Command Window on the SMA, a Windows Workstation or a Windows Server
that can access the SMA by TCP/IP or the management host running Command View.
1. Click Run on the Window Start menu.
2. Enter cmd in the Open eld to open the DOS Command Window.
3. Change to the directory (CD) in which you have installed SSSU. For example, C:> cd \SSSUDir
4. Enter SSSU to run the application.
5. Enter SELECT MANAGER <SMAname or ip_addr> user=<username> pass=<userpass-
word>.
6. Enter SHOW SYSTEM to display the EVA storage systems managed by the SMA or Windows Host.
7. Enter SELECT SYSTEM <EVA_Name>,whereEVA_name is the name of the storage system.
The storage system name is case sensitive. If there are spaces between the letters in the name, quotes
must enclose the name. For example, SELECT SYSTEM “Large EVA”.
8. Enter CAPTURE CONFIGURATION <pathname\filename>,wherepathname identies the
location where the conguration les will be saved, and filename isthenameusedastheprexfor
the congurations les. For example, CAPTURE CONFIGURATION c:\EVAConfig\LargeEVA
9. Enter EXIT to close the DOS Command Window.
Exam ple 2 . Restoring co n guration d ata usin g SSSU on a Windows H ost
If it is necessary to restore the storage system conguration, it can be done using the
1. Click Run on the Window Start menu.
2. Enter cmd in the Open eld to open the DOS Command Window.
3. Change to the directory (CD) in which you have installed SSSU. For example, C:> cd \SSSUDir
4. Enter SSSU to run the application.
5. Enter FILE <pathname\filename>,wherepathname identi
es the location where the
conguration les are be saved and lename isthenameoftherst conguration le. F or example,
FILE c:\EVAConfig\LargeEVA_Step1A.txt
6. Repeat the preceding step for each conguration le.
Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)
51