Instruction Manual

4. Wait three m inutes and then verify that all disk drives are ready. The drive ready indicator and
the drive online indicator should b e on (green).
5. Power on the upper HSV controller. It will assume the roll of master controller.
6. Wait 10 seconds and then power on the lower controller. It will assume the roll of slave controller.
7. Verify that the (Operator Control Panel) OCP display on each controller displays the storage system
name and the EVA WWID.
8. Launch Command View EVA and verify connection to the storage system. If the storage system is
not visible, click the HSV Storage Network icon in the Navigation pane to discover the recently
restarted storage system.
NOTE:
If the storage system is still not seen, it may be necessary to reboot the SMA to re-establish
the communication link.
9. Check the array status using Command View EVA to ensure everything is operating properly. If any
status indicator is not normal, check the log lesorcontactyourHPserviceproviderforassistance.
Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)
43