Instruction Manual
Displaying Detailed Information
The Detail View menu lets you examine detailed fault information stored in the Last Termination Event
Array (LTEA). T
his array stores information for the last 32 termination events.
Complete the following procedure to d isplay the LTEA information about any of the last 32 termination
events:
1. When the Fault M
anagement display is active (flashing), press
to select the Detail View menu.
The LTEA selection menu is active (LTEA 0 is displayed).
2. Press
or to increment to a specific error, LTEA N, in this example.
3. Press
to observe data about the selected error, LTEA N, in this example.
Interpreting Fault Management Information
Each version of the HP Command View EVA application includes an ASCII text file that defines all the
codes that th
e authorized service representative can view either on the GUI or on the OCP.
IMPORTANT:
Thisinformationisfortheexclusiveuseoftheauthorizedservicerepresentative.
The file name identifies the file type and the revision date. For example, the file name
hsv110_event_w010605_t100.txt provides the following information:
• hsv110_—the Network Storage Controller (NSC) model number string, that is the controller
model number
• event_—the t ype of information in the file.
• w010605_—the NSC base level build string, that is, the file creation date.
• 01—creation year
• 06—creation month
• 05—creation date
• t100—the NSC software version number string.
Table 55 describes types of information available in this file.
Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)
157