Instruction Manual

0.F.en.02 CRITICAL Condition—Transceiver Data Signal Lost
This symptom can occur when a controller has been powered off or a cable has been removed from
the transceiver
. The transceiver can no longer detect a data signal. This error prevents the controller
from transferr
ing data on a loop and eliminates the enclosure dua l-loop capability. This error remains
active until th
eproblemisxed.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representativ e.
0.F.en.03 CRITICAL Condition—Transceiver FC-AL Bus Fault
The system has detected an FC-AL bus fault involving a transceiver. This error prevents the controller from
transferring data on a loop ad eliminates the enclosure dual-loop capability.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Check all the transceivers and cables to ensure they are properly connected.
3. Check all the transceivers on the loop to ensure they are compatible with the I/O module.
4. If the problem persists, contact your HP authorized service representative.
0.F.en.04CRITICALConditionTransceiverRemoved
The EMU dete
cts that a transceiver has been removed. This error remains active until the problem is xed.
Theerrorcanbeclearedbydoingoneofthefollowing:
1. Install a new transceiver,
or
Recongure the system by switching from a loop topology to one with Vixel switches, then the
transceiver is not necessary.
2. Clea r the e
rror by resetting the EMU or by removing and then re-installing the I/O module.
0.F.en.05 CRITICAL Condition—Invalid Fibre Channel Character
This symptom can occur under the following conditions:
The incoming data stream is corrupted.
A cable is not completely connected.
The signal is degraded.
This error prevents the controller from transferring da ta on a loop and eliminates the enclosure dual-loop
capability. This error remains active until the problem is xed.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representativ e.
Voltage sensor and current sensor conditions
The format of these sensor condition reports is 1. 2. e n. e c for a voltage sensor, and 1. 3. e n . e c for a
current sensor, where:
1. 2. is t
he voltage sensor element t ype
1. 3. is the current sensor element type number
en. is the sensor element number
ec is th
eerrorcode
Table 54 lists the location of the power supply voltage and current sensors.
Enterprise Virtual Array 3000/5000 user guide (VCS 3.110)