Instruction Manual

1. Record all six characters of the condition report.
2. Ensure that the blower on the power supply is functioning properly. If not, correct the blower
condition a nd wait one minute.
3. Contact your authorized service representative.
Blower conditions
The format of a
blower condition report is 0.3.en.ec,where:
0.3.istheblower element type number
en. is the two-character blower element num ber
ec is the erro
rcode
As shown in Figure 61, blower 1 is in location 1 and b lower 2 is in location 2.
CXO7953
A
21
Figure 61 Blower element numbering
CAUTION:
Asingleblower operatingathighspeedcanprovidesufcient air ow to cool an enclosure and the
elements for up to 100 hours. However, operating an enclosure at temperatures approaching an
overheating threshold can damage elements and may reduce the MTBF of a specic element. Immediate
replacement of the defective blower is required.
The following sections dene the power supply condition reports.
0.3.en.01 NONCRITICAL condition—Blower speed
A blower is operating at a speed outside of the EMU specied range, possibly because of a bearing
problem. This can affect enclosure cooling and cause an element to fail. This condition report remains
active until the problem is corrected.
This error does not normally require immediate correction. However, an error of this type could contribute
to an elem ent overheating.
HP recommends replacing the blower as soon as possible.
To correct this problem, record all six characters of the condition report, then contact your HP authorized
service representative.
0.3.en.02CRITICALconditionBlowerspeed
A blower is operating at a speed that is signicantly outside the EMU specied range, possibly because
of a bearing problem. This can cause the loss of cooling and cause an element to fail. The error remains
active until the problem is corrected.
HP recommends replacing the blower as soon as possible.
14 0
EMU generated condition reports