This error remains active u ntil the problem is corrected.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Remove and replace the drive in the enclosure.
3. ObservethedrivestatusLEDstoensurethedriveisoperational.
4. Observe the EM U to ensure the error is corrected.
5. If removing and replacing the drive did not correct the problem, replace the drive.
6. ObservethedrivestatusLEDstoensurethedriveisoperational.
7. Observe the EM U to ensure the error is corrected.
8. If unable to correct the problem, contact your authorized service representative.
0.1. en.05 CRITICAL condition—Loop B drive link rate incorrect
The drive is capable of operating a t the loop link rate but is running at a different rate. For example, the
drive is ope
rating at 1G bps, and the loop is operating at 2 G bps. Only when the drive is operating at the
Fibre Chan
nel link rate established by the I/O module can this drive transfer data.
This error remains active u ntil the problem is corrected.
Complete the following procedure to correct this problem:
1. Record all six characters of the condition report.
2. Remove and
replace the drive in the enclosure.
3. ObservethedrivestatusLEDstoensurethedriveisoperational.
4. Observe the EM U to ensure the error is corrected.
5. If removi
ng and replacing the drive did not correct the problem, replace the drive.
6. ObservethedrivestatusLEDstoensurethedriveisoperational.
7. Observe the EM U to ensure the error is corrected.
8. If unabl
e to correct the problem, contact your authorized service representative.
Power supply conditions
The format of a power supply condition report is 0.2.en.ec,where:
0.2. is the power supply element type number
en. is the two-character power supply element number
ec is the error co d e
Figure 60 shows the location of power supply 1 and power supply 2.
138
EMU generated condition reports