Instruction Manual
Table 41 AC input current and wattage
Nominal
Maximum
Input voltage
Amps Watts Amps Watts
60-Hz Input
100 VAC–JBO D 4.35 436 6.41 641
208 VAC–North America
2.03
419 2. 94
609
50-Hz Input
12 0 VAC – J B O D
3.59
419
5.27 633
220 V AC–North America
1. 9 2
418
2.78 608
230 VAC–Nort
hAmerica
1. 9 2
418
2.78 608
240 VAC–Europe
1. 76
416
2.55 607
Table 42 C ontroller power supply output specifications
Voltage Spec
ification
Minimum
Nominal
Maximum
+3.3 VDC
Output VoltageSteady state curr ent
Power
3.23 VDC 3.30 VDC
3.36 VDC 18 A
1
59 .4W
+5.0 VDC
Output Voltage Steady state current
Power
4.90 VDC
5.00 VDC
5.10 VDC 4 A 20.0W
+12.0 VDC
Output Vol
tage Steady state current
Power
11. 4 V D C
12.0 V D C
12. 6 V D C 2 A 4 .0 W
Total Current Total Power
24 A 65.4W
1
1
+3.3 VDC steady state current requires a minimum 5.0-V load of 1 A.
Environm
ental specifications
There are no controller environmental specifications. See the Rack environm ental specifications for this
informa
tion in the next section.
Rack
Physical specifications
WARNING!
The weight of the drive enclosure with the elements installed a lways requires at least two individuals to
move. HP recommends using a fork lift or a hand truck to move an enclosure in the shipping container.
Table 43 through Table 48 define the dimensions and weights of the 9000-Series and 10000-Series
Enterprise Virtual Array racks.
13 0
Regulatory notices and specifications