ALM-1 501-1157 (Pedestal Systems)
The ALM-1 must be installed in Slots 11 and 12. Install Backplane Jumpers BG3 and IACK in Slot
11. Remove Backplane Jumper BG3 from Slot 12.
MAPkit
The MAPkit requires two slots. Remove Backplane Jumpers BG3 and IACK from the slot that
contains the MAPkit board nearest to Slot 1. Install Backplane Jumpers BG3 and IACK in the
second slot.
1.
The MAPkit data throughput rate may be affected if a Tape Controller or a Disk Controller is
installed in an unused slot between the CPU and the MAPkit.
2.
SunLink Channel Adapter
The SCA requires two slots. Remove Backplane Jumpers BG3 and IACK from both slots.1.
Installing a 1/2" Tape Controller or an SMD Controller in an unused slot between the CPU and
the SCA option may affect the SCA data throughput rate.
2.
12-Slot Office Pedestal Backplane 501-1382
A cutout in the upper left corner of the 501-1382 Backplane allows the DC Wire Harness to be routed
from the rear of the Backplane to the front of the Peripheral Tray.
VME to Multibus Adapter Board
Use Adapter board subassembly 501-1054-04, Rev. A, or greater, to avoid signal contention on the P2
bus. This change was effective in September 1985 (ECO 1850).
Sun4/I: Slot Assignment - Board Installation Notes