Datasheet

Protocol Support
Protocol SupportProtocol Support
Protocol Support
Wide Ultra3 (LVD)
Wide Ultra2 (LVD)
O/S Support
O/S SupportO/S Support
O/S Support
Defined by specific HP array controller or SCSI adapter used; please refer to the QuickSpecs and/or User Guide of the specific
array controller or SCSI adapter
Dimensions (HxWxD)
Dimensions (HxWxD)Dimensions (HxWxD)
Dimensions (HxWxD)
Tower
Rack
22.5 x 13.25 x 23 in (56.7 x 33.9 x 57.96 cm)
5.2 x 19 x 20.5 in (13.1 x 47.88 x 51.66 cm)
Shipping Dimensions
Shipping DimensionsShipping Dimensions
Shipping Dimensions
(HxWxD
(HxWxD(HxWxD
(HxWxD
Tower
Rack
Redundant Power Supply
34.25 x 14.5 x 31.25 in (86.31 x 36.54 x 78.75 cm)
34.25 x 14.5 x 31.25 in (86.31 x 36.54 x 78.75 cm)
3.75 x 8.0 x 12.75 in (9.52 x 20.32 x 32.38 cm)
Weight
WeightWeight
Weight
Tower
Rack
Redundant Power Supply
93 lb (42.8 kg)
68 lb (30.9 kg)
6.6 lbs (3.0 kg)
LED Indicators
LED IndicatorsLED Indicators
LED Indicators
(on front panel)
(on front panel)(on front panel)
(on front panel)
EMU Status LED (left)
Enclosure Power LED (middle)
Fault LED (right)
Drive LED Indicators
Drive LED IndicatorsDrive LED Indicators
Drive LED Indicators
(on drive trays)
(on drive trays)(on drive trays)
(on drive trays)
Drive LED (top)
On Line LED (middle)
Drive Failure LED (bottom)
Enclosure LED
Enclosure LEDEnclosure LED
Enclosure LED
Indicators (back of
Indicators (back ofIndicators (back of
Indicators (back of
unit)
unit)unit)
unit)
I/O Module (top)
EMU (middle)
Power supplies (bottom)
Input Requirements
Input RequirementsInput Requirements
Input Requirements
Nominal Line Voltage
Range Line Voltage
Line Frequency
Typical Input Current
110 to 240 V AC
90 to 264 V AC
47 to 63 Hz
2.3A at 120 V AC
Relative Humidity
Relative HumidityRelative Humidity
Relative Humidity
(non-condensing)
(non-condensing)(non-condensing)
(non-condensing)
Operating
Shipping
10% to 90%
5% to 90%
Enclosure LED
Enclosure LEDEnclosure LED
Enclosure LED
Indicators (back of
Indicators (back ofIndicators (back of
Indicators (back of
unit)
unit)unit)
unit)
Smart Array 6402
Smart Array 5302/128
Smart Array 5312
Smart Array 5304/256
Smart Array 642
NOTE:
NOTE:NOTE:
NOTE:
Supported at Ultra2 speeds
Smart Array 532
Smart Array 5i/5i Plus
NOTE:
NOTE:NOTE:
NOTE:
Single external SCSI channel supported on select ProLiant Servers. See Server QuickSpecs for specific model
information.
HSG80 Controller
HSG60 Controller
64-bit Dual Channel Wide Ultra3 SCSI Adapter
1 channel Wide Ultra2 Adapter (AlphaStations)
1 channel Wide Ultra2 Adapter (AlphaServer systems)
NOTE:
NOTE:NOTE:
NOTE:
See your server and controller compatibility matrix for details on controller and server compatibility.
Power
PowerPower
Power
377 Watts per supply (load)
BTU (220 volts)
BTU (220 volts)BTU (220 volts)
BTU (220 volts)
Single power supply 14 drives
Single power supply 5 drives
Single power supply 1 drive
Dual power supply 14 drives
Dual power supply 5 drives
Dual power supply 1 drive
1164 BTUs/hour
536 BTUs/hour
273 BTUs/hour
1232 BTUs/hour
625 BTUs/hour
352 BTUs/hour
Temperature Range
Temperature RangeTemperature Range
Temperature Range
Operating
Shipping
50° to 94° F (10° to 35° C )
-40° to 151° F (-40° to 66° C)
NOTE:
NOTE: NOTE:
NOTE:
To maintain proper cooling and airflow, a drive blank or drive must occupy all bays during operation.
QuickSpecs
HP StorageWorks 4300 Enclosure
HP StorageWorks 4300 EnclosureHP StorageWorks 4300 Enclosure
HP StorageWorks 4300 Enclosure
Technical Specifications
DA - 10624 Worldwide — Version 16 — December 17, 2003
Page 8