User's Guide
5-6
Verifying Jukebox Operation and Labeling
Restore Non-Default Configurations
Table 5-2 Description of the Configuration Choices
Configuration
Name
Description
RECOVERY
ON/OFF
Toggles between ON and OFF. If set to ON, the jukebox
attempts to recover from errors. If set to OFF, the
jukebox immediately stops moving if an error
condition occurs. The default configuration is
RECOVERY ON
, and recovery should remain ON under
normal conditions.
DUAL PICKER
ON/OFF
Toggles between ON and OFF. If set to ON, the jukebox
runs with dual picker addressing ON. If set to OFF, the
jukebox runs with dual picker addressing OFF. The
default setting is DUAL PICKER ON and this mode
should remain ON under normal conditions. .
SECURE MS
ON/OFF
Toggles between ON and OFF. If set to ON, loading and
ejecting disks is disabled. If set to OFF, loading and
ejecting disks is enabled. The default configuration is
ON.
SLTS 230-238
ON/OFF
Toggles between ON and OFF. If set to ON, Slots 230 to
238 are made accessible to a software application. If
set to OFF, slots 230 to 238 are made unavailable; slot
229 becomes the last available slot.
The default configuration is ON
This configuration accommodates applications that do
not support slots 230 to 238.
POWER SECURE
ON/OFF
Toggles between ON and OFF. If set to ON, the
selection of the SECURE MS configuration is retained
through power cycling (or power outage). If set to
OFF, the jukebox returns to the default setting of this
configuration after a power cycling. The default setting
of this configuration is OFF).