The VC Module MIB is a VC-specific MIB that describes the state of a specific VC module. In addition to
unique VC module attributes, it defines traps for reporting alerts on port statistics, such as throughput, errors,
and discards. The VC Domain MIB combines domain-wide attributes with traps for state changes in VC
managed objects.
The latest version of the VC-specific MIBs, 8.30b or higher, can be downloaded from the HP Systems Insight
Manager "MIB Kit" site on the HP website
(http://h18006.www1.hp.com/products/servers/management/hpsim/mibkit.html).
SNMP traps
The following table provides a summary of the available SNMP traps.
Trap Category Severity MIB
cpqHoSWRunningStatusChangeTrap
VCM Legacy Corresponds to the
new value of
cpqHoSWRunningStat
us
CPQHOST-MIB
connUnitStatusChange
VC-FC Other INFO FA-MIB
connUnitDeletedTrap
VC-FC Other INFO FA-MIB
connUnitEventTrap
VC-FC Other INFO FA-MIB
connUnitSensorStatusChange
VC-FC Other CRITICAL FA-MIB
connUnitPortStatusChange
VC-FC Port Status See table below FA-MIB
authenticationFailure¹
VC-FC Other CRITICAL SNMPv2-MIB
coldStart
VC-FC Other CRITICAL SNMPv2-MIB
cpqHoSWRunningStatusChange
VC-FC Other INFO CPQHOST-MIB
authenticationFailure
VC-Enet Other CRITICAL SNMPv2-MIB
Domain status change
VCM Domain Status Corresponds to the
name of the new state
VCD-MIB
StackingLinkRedundant status change
VCM Domain Status Corresponds to the
name of the new state
VCD-MIB
Module role change
VCM Domain Status INFO VCM-MIB
Stale checkpoint
VCM Domain Status WARNING VCD-MIB
Valid checkpoint
VCM Domain Status NORMAL VCD-MIB
Enclosure status change
VCM Domain Status Corresponds to the
name of the new state
VCD-MIB
Network status change
VCM Network Status Corresponds to the
name of the new state
VCD-MIB
Fabric status change
VCM Fabric Status Corresponds to the
name of the new state
VCD-MIB
VC module status change
VC-Enet Module Status or
VC-FC Module Status
Corresponds to the
name of the new state
VCD-MIB
Profile status change
VCM Profile Status Corresponds to the
name of the new state
VCD-MIB
Physical server change
VCM Server Status Corresponds to the
name of the new state
VCD-MIB
vcTesttrap
VCM Domain Status INFO VCD-MIB
Enet IF-MIB LinkDown
VC-Enet Port Status INFO IF-MIB
Enet IF-MIB LInkUp
VC-Enet Port Status NORMAL IF-MIB
Input utilization above high-water mark²
VC-Enet Port Threshold WARNING VCM-MIB
Input utilization below low-water mark²
VC-Enet Port Threshold NORMAL VCM-MIB