Manual
Virtual Connect modules 203
Server Bay VC Status icon definitions
Icon Operational state Meaning Corrective action
OK Device is fully operational. None
Unknown Device operational state cannot be
determined.
Check Onboard Administrator
communication.
Disabled Device is disabled. Enable the component in Virtual
Connect Manager.
(blue)
Initializing Device is initializing. Wait until initialization is complete.
(This icon should only be seen at
startup.)
(blue)
Profile pending Device has a pending profile
assignment.
Turn server power off and apply the
new profile.
(yellow)
Degraded Device is partially operational, but
capacity is lost.
Check and correct the Onboard
Administrator error condition.
(orange)
Misconfigured Device has a configuration error. Correct the Virtual Connect Manager
configuration attributes.
(orange)
Incompatible Device does not match the
configuration.
BIOS level is not at a level that supports
Virtual Connect.
(orange)
No communication Cannot communicate with the
device.
Check the physical connections and IP
address.
Missing Device is configured but not
accessible.
Insert the correct hardware module.
Failed Device is not operational because
of an error.
Reset the device or application, or
replace the device.
Server Bay OA Communication Status icon definitions
Icon Operational state Meaning Corrective action
OK Device is fully operational. None
Failed Cannot communicate with the
device.
Do one or more of the following:
•
Reset the interconnect module.
•
Check if the physical device is
properly seated in the bay.
•
Check the IP address.