Manual
Table Of Contents
- HP Virtual Connect for c-Class BladeSystemVersion 3.01User Guide
- Notice
- Contents
- Introduction
- Overview
- HP Virtual Connect Manager
- Domain management
- Domain overview
- Firmware updates
- Domain Settings (Domain Configuration) screen
- Domain Settings (Domain IP Address) screen
- Domain Settings (Domain Enclosures) screen
- Domain Settings (Backup/Restore) screen
- Domain Settings (Local Users) screen
- Directory Settings (Directory Server) screen
- Directory Settings (Directory Groups) screen
- Directory Settings (Directory Certificate) screen
- Test LDAP authentication
- SNMP overview
- System Log screen
- System Log Configuration
- Network management
- Networks overview
- Define Ethernet Network screen
- Edit Ethernet Network screen
- Ethernet Networks (External Connections) screen
- Ethernet Networks (Server Connections) screen
- Ethernet Settings (MAC Addresses) screen
- Ethernet Settings (Port Monitoring) screen
- Ethernet Settings (Advanced Settings) screen
- Stacking Links screen
- Shared uplink sets and VLAN tagging
- Define Shared Uplink Set screen
- Shared Uplink Sets (External Connections) screen
- Shared Uplink Sets (Associated Networks) screen
- Storage management
- Server management
- Certificate Administration
- Hardware information screens
- Enclosure Information screen
- Enclosure Status screen
- Interconnect Bays Status and Summary screen
- Causes for INCOMPATIBLE status
- Interconnect Bay Summary screen (Ethernet module)
- Interconnect Bay Summary screen (VC-FC Module)
- Module removal and replacement
- Interconnect Bay Overall Status icon definitions
- Interconnect Bay OA Reported Status icon definitions
- Interconnect Bay VC Status icon definitions
- Interconnect Bay OA Communication Status icon definitions
- Server Bays Summary screen
- Server Bay Status screen
- Acronyms and abbreviations
- Glossary
- Index

Glossary 159
Glossary
external port
The Ethernet connectors (10GBASE-CX4 and RJ45) on the faceplate of the VC-Enet module labeled as
ports 1-8, X1, and X2.
shared server links
A feature that enables each server link to be shared among multiple networks with the use of VLAN
tagging.
shared uplink port
An Ethernet uplink port that carries the traffic for multiple Virtual Connect networks. Each associated
Virtual Connect network is mapped to a specific VLAN on the external connection and appropriate VLAN
tags are removed or added as Ethernet packets enter or leave the Virtual Connect domain.
shared uplink port set
A set of Ethernet uplinks that are used together to provide improved throughput and availability to a
group of associated Virtual Connect networks. Each associated Virtual Connect network is mapped to a
specific VLAN on the external connection and appropriate VLAN tags are removed or added as Ethernet
packets enter or leave the Virtual Connect domain.
Smart Link
A feature that, when enabled, configures a Virtual Connect network so that if all external uplinks lose link
to external switches, Virtual Connect will drop the Ethernet link on all local server blade Ethernet ports
connected to that network.
stacking port
A VC-Enet module external port used to connect to other VC-Enet modules within an active Virtual Connect
domain. Stacking ports are automatically identified by the VC-Enet modules. The port number (port ID) is
lit amber.
uplink port
An external port that is configured within Virtual Connect for use as a connection to external networking
equipment. Uplink ports are defined within Virtual Connect by the enclosure name, interconnect bay
containing the module, and the port number. The port number (port ID) for uplink ports is lit green.
uplink port set
A set of uplinks that are used together to provide improved throughput and availability for a single Virtual
Connect network connection to external networking equipment.