Manual
Domain management 44
Trap Category Severity MIB
connUnitSensorStatusChange
VC-FC Other CRITICAL FA-MIB
connUnitPortStatusChange
VC-FC Port Status See table below FA-MIB
authenticationFailure*
VC-FC Other CRITICAL SNMPv2-MIB
coldStart
VC-FC Other CRITICAL SNMPv2-MIB
cpqHoSWRunningStatusChange
VC-FC Other INFO CPQHOST-MIB
authenticationFailure
VC-Enet Other CRITICAL SNMPv2-MIB
Domain status change
VCM Domain Status Corresponds to the
name of the new state
VCD-MIB
StackingLinkRedundant status change
VCM Domain Status Corresponds to the
name of the new state
VCD-MIB
Module role change
VCM Domain Status INFO VCM-MIB
Stale checkpoint
VCM Domain Status WARNING VCD-MIB
Valid checkpoint
VCM Domain Status NORMAL VCD-MIB
Enclosure status change
VCM Domain Status Corresponds to the
name of the new state
VCD-MIB
Network status change
VCM Network Status Corresponds to the
name of the new state
VCD-MIB
Fabric status change
VCM Fabric Status Corresponds to the
name of the new state
VCD-MIB
VC module status change
VC-Enet Module Status or
VC-FC Module Status
Corresponds to the
name of the new state
VCD-MIB
Profile status change
VCM Profile Status Corresponds to the
name of the new state
VCD-MIB
Physical server change
VCM Server Status Corresponds to the
name of the new state
VCD-MIB
vcTesttrap
VCM Domain Status INFO VCD-MIB
Enet IF-MIB LinkDown
VC-Enet Port Status INFO IF-MIB
Enet IF-MIB LInkUp
VC-Enet Port Status NORMAL IF-MIB
Input utilization above high-water mark
VC-Enet Port Threshold WARNING VCM-MIB
Input utilization below low-water mark
VC-Enet Port Threshold NORMAL VCM-MIB
Output utilization above high-water
mark
VC-Enet Port Threshold WARNING VCM-MIB
Output utilization below low-water mark
VC-Enet Port Threshold NORMAL VCM-MIB
Input errors above high-water mark
VC-Enet Port Threshold
WARNING
VCM-MIB
Input errors below low-water mark
VC-Enet Port Threshold NORMAL VCM-MIB
Output errors above high-water mark
VC-Enet Port Threshold WARNING VCM-MIB
Output errors below low-water mark
VC-Enet Port Threshold NORMAL VCM-MIB
* Only supported by the HP VC 8Gb 24-Port FC module
For more information, see the description field in the source code for individual MIBs.
The VC-FC module generates connUnitPortStatusChange traps based on changes to the connUnitPortStatus
element of the FA-MIB. The following table shows the mapping of connUnitPortStatusChange trap severities
to the VC Domain MIB's trap severity definitions.