Manual

Hardware information screens 177
Icon Operational state Meaning Corrective action
(yellow)
Failed Device is not operational because
of an error.
Check and correct the Onboard
Administrator error condition.
Interconnect Bay VC Status icon definitions
Icon Operational state Meaning Corrective action
OK Device is fully operational. None
Unknown Device operational state cannot be
determined.
Check Onboard Administrator
communication.
Disabled Device is disabled. Enable the component in Virtual
Connect Manager.
(blue)
Initializing Device is initializing. Wait until initialization is complete.
(This icon should only be seen at
startup.)
(blue)
Unavailable Device is active but unable to
provide service.
Attempt to re-establish connection.
(yellow)
Degraded Device is partially operational, but
capacity is lost.
Check and correct the Onboard
Administrator error condition.
(orange)
Misconfigured Device has a configuration error. Correct the Virtual Connect Manager
configuration attributes.
(orange)
Incompatible Device does not match the
configuration.
Remove the incorrect hardware. Insert
the correct module.
(orange)
No communication Cannot communicate with the
device.
Check the physical connections and IP
address.
Missing Device is configured but not
accessible.
Insert the correct hardware module.
Failed Device is not operational because
of an error.
Reset the device or application, or
replace the device.
Interconnect Bay OA Communication Status icon definitions
Icon Operational state Meaning Corrective action
OK Device is fully operational. None
Failed Cannot communicate with the
device.
Do one or more of the following:
Reset the interconnect module.
Check if the physical device is
properly seated in the bay.
Check the IP address.