Hardware information screens 162
• FC modules in multi-enclosure double dense domains
Multi-enclosure double dense domains require similar and compatible FC modules in bays 5, 6, 7, and
8 in all enclosures. If a multi-enclosure double dense configuration contains incompatible FC modules in
bays 5, 6, 7, or 8 in either the local or remote enclosures, some or all of the compatible FC modules in
the remote enclosures might be designated INCOMPATIBLE after import.
Corrective action:
a. Replace incompatible FC modules with similar and compatible FC modules in bays 5, 6, 7, and 8
in all enclosures.
b. Power cycle any FC module that still remains in an INCOMPATIBLE state.
Interconnect Bay Summary screen (Ethernet module)
This screen provides a summary of the interconnect module status and port information. To remove a module,
see "Special notes on interconnect module removal and replacement (on page 175)."
The following table describes the rows within the Interconnect Bay Status (VC-Enet Module) table in the Bay
Summary screen.