Web-Based Enterprise Services  Release Notes 1–21
Workaround 
• Define system PATH variable with some value (not null) before installing.
• Manually add WCCProxy path to PATH after installation.
1.6.2.14 Windows Itanium Installation may interrupt if PATH 
variable is 256 characters or longer 
In case of Windows Itatium, if the system PATH variable is 256 characters or longer then 
during the WCCProxy installation an error dialog box pops up “Failed to get PATH”. The 
reason behind is that, post installation the PATH variables only contains WEBES 
path.WCCProxy path is not added. As a result of this, WCCProxy commands like 
“wccproxy status” do not work.
Workaround: 
• Remove junk entries from PATH. 
• Manually add WCCProxy path to PATH after installation. 
1.6.3 Linux WEBES Issues 
These issues apply to WEBES on Red Hat Linux: 
1.6.3.1 Director May Require Restart 
If the system is configured to restart in graphical user interface mode (run level 5), the desta 
Director may not always automatically restart. For run level 5, always restart the Director 
manually after any type of system restart: 
# desta start 
Linux systems that restart in command-line mode (run level 3) correctly restart the desta 
Director automatically whenever the system restarts. 
1.6.3.2 Segmentation Fault Error Message 
If you had installed an ISEE Client containing WCCProxy 1.0, when installing WEBES you 
may see the following error message when the WCCProxy is stopped (so that it can be 
replaced with the newer version bundled in WEBES): 
Stopping the WCCProxy. 
/usr/sbin/wccproxy: line 122: 10052 Segmentation fault 