user manual
Overall WEBES Release Notes
1.6 WEBES Known Issues
Rev. 9/8/06
1–12 Web-Based Enterprise Services Release Notes
Running a local copy of WEBES for analysis only on that local system does not present a 
problem. Likewise, connecting directly to a remote system via the CLI or web URL (for 
example, without having WEBES installed on your local system) is okay. 
To avoid a compatibility issue, make sure that the exact same version of WEBES is installed 
on all systems that will connect to one another, as within a given site or enterprise. In any 
clustered environment, it is especially important to have the same version (including dot 
release or Service Pak) installed on every node. Backward compatibility will be introduced in 
a future WEBES release. 
1.6.1.9 Director Process Not Responding 
If one of the WEBES components is not responding or giving an error, it may be that the 
Director process is not responding. To correct this problem, see the Director chapter in the 
WEBES User Guide. It includes a section on troubleshooting an unresponsive Director 
process. 
1.6.1.10 Director Process Stopping When Out of Memory 
If the Director hangs or terminates unexpectedly, check the Director log files (see the WEBES 
User Guide for more information on log files). If the log files contain errors mentioning “out 
of memory” conditions, one of the following conditions may apply: 
• Your system has run out of memory or paging space. 
• The Director process has reached its Java memory limits. These limits are set during 
WEBES installation, but may be overridden by a user. 
If the Java memory limits are responsible for the problem, you can raise the memory limits 
applied to the Director process and its subprocesses. After the limits have been increased, you 
can restart the Director and perform the actions that caused the out of memory error. The limits 
can be set as high as necessary, and are only constrained by the memory and paging space 
available on the system. Refer to the WEBES User Guide for details on adjusting the memory 
limits. 
1.6.1.11 Upgrade Requires Reinitialized Log 
If you are running SEA (formerly Compaq Analyze), reinitialize the system error log as 
described in the platform-specific sections of the WEBES Installation Guide before 
performing a WEBES upgrade. 
Otherwise, up to seven days of repeat (previously seen) problem reports may appear. This 
behavior occurs because of an issue where SEA re-scans the entire log after the upgrade. 
Normally, SEA scans the entire log only after a fresh installation. 










