user manual
Table Of Contents
- TR.PDF
- 1.PDF
- 2.PDF
- Hardware Installation
- Introduction
- Site Preparation
- Assembly
- Installing the LCS60
- Rack Mounting
- Wall Mounting
- Table-Top Mounting
- Connecting the System Console
- Direct Connection to the LCS60
- Connection through a Data Switch
- Connection through Modems
- Connection through StarKeeper II NMS
- Connecting the Fiber Interface
- Configuration of the Lucent Technologies Data Switch ± LCS60
- Power and Grounding
- Verify LCS60 Console Connection
- Verify Fiber Connection
- Configure the LCS60
- LAN Connections
- Hardware Installation
- 3.PDF
- 4.PDF
- 5.PDF
- 6.PDF
- 7.PDF
- 8.PDF
- Administration
- Basics
- Logging On
- lcsadm Interface
- Typical Administrative Tasks
- Backup and Restore Operations
- Network Access Password Option
- Status
- Error Messages
- Administration
- 9.PDF
- 10.PDF
- 11.PDF
- 12.PDF
- 13.PDF
- 14.PDF
- 15.PDF
- 16.PDF
- IX.PDF

Hardware
Installing the LCS60
Screen 2-2: continued
DIRECTION [originate, receive, 2way]: receive
DEVICE OR HOST [up to 8 chars: +(standard)]: morscon
HOST AUTOBAUD [on, off: +(off)]: off
ROUND ROBIN SERVICE [per_port, per_module, none: +(none)]: Return
Creating New Host: morscon
CC0> enter msm
COMPONENT [module, port]]: p
MODULE ADDRESS: 18
PORT NUMBER [1-12: +(1-12)]: 11
CC0> enter group
GROUP [up to 8 chars]: gmorscon
CONNECTED TO 2-WIRE MODEM [yes, no: +(no)]: Return
BAUD RATE [75, 110, 150, 300, 1200, 2400, 4800, 9600, 14400
19200, 28800, 38400, 57600, 76800, 115200: +(9600)]: Return
PARITY [off, even, odd: +(off)]: Return
FLOW CONTROL OF MSM BY DEVICE [xon_xoff, eia, none: +(eia)]: none
FLOW CONTROL OF DEVICE BY MSM [xon_xoff, eia, none: +(eia)]: xon
VDM ON THIS PORT [yes, no: +(no)]: Return
PERMANENTLY ACTIVATED PORT [yes, no: +(no)]: y
BITS PER CHARACTER [5, 6, 7, 8: +(8)]: Return
NUMBER OF STOP BITS [1, 1.5, 2: +(1)]: Return
ENDPOINT NUMBER OR RANGE [0000-9999, none: +(none)]: Return
PORT NUMBER [1-12: +(1-12)]: Delete
CC0> enter address
LEVEL [local, area, exchange, local, speedcall: +(local)]: local
TYPE [numeric, mnemonic, both: +(mnemonic)]: Return
MNEMONIC ADDRESS [up to 8 chars]: morscon
PAD SUPPORT [yes, no: +(no)]: Return
DIRECTORY ENTRY [up to 30 chars double quoted, none: +(none)]:
"console to morse"
GROUP(S) [up to 4 groups separated by commas, none: +(none)]:
gmorscon
ORIGINATING GROUP NAME SECURITY PATTERN(S)
[comma-separated pattern list, same_as, none: +(none)]: Return
INITIAL SERVICE STATE [in, out: +(out)]: in
LEVEL [network, area, exchange, local, speedcall: +(local)]: Delete
CC0> restore msm
COMPONENT [module, port]]: p
MODULE ADDRESS: 18
PORT NUMBER [1-12: +(1-12)]: 11
CC0>
Issue 3 2-15