226 Managing supplies ENWW
25 Pinch the release tab on the left roller and pull the roller off of
the rod. Remove the roller on the right side. Slide the blue
cover to the left, and then remove the bottom roller.
26 Grasp both sides of the new bottom roller and slide it onto the
rod until it clicks into place. Install the roller on the right side,
and then install the left roller. Slide the blue cover to the right.
27 Replace the media in the 2,000-sheet side input tray (tray 4),
making sure that the guides fit snugly against the media, and
then slide the tray toward the MFP. The two plastic hooks on
the tray lock into the pedestal.
28 If NEW TRANSFER KIT appears on the control-panel display,
touch Y
ES. The kit life-count is automatically reset.
29 If NEW TRANSFER KIT does not appear, press the M
ENU button
to open the menus. Scroll to CONFIGURE DEVICE, to RESETS,
and then to RESET SUPPLIES. Scroll to NEW TRANSFER KIT, and
then touch Y
ES to reset the count.
Note
If you select NO or do not make a selection, the MFP remains
offline until you replace the kit and select YES.
30 Place the used parts in the packaging from the new ones. For
recycling information, see the recycling guide that is included
with the new image transfer kit.