user manual

Setting the host mode and host group mode for the disk array ports
After the disk array is installed, you must set the host mode for each disk array por t to match the host OS.
Set the host mode using LUN Manager in Remote We b Console (shown), Command View (XP arrays
only), or Command View XP Advanced Edition. If these are not available, the HP service representative
can set the h
ost mode using the SVP.
TheavailablehostmodesettingsforWindows2000/2003areasfollows:
Host mode
Description
2C (ava
ilable on some array models)
HP reco
mmended. (For use with LUSE volumes when
online
LU N expansion is required or may be required
in the f
uture.)
0C
HP recommended. (Use if future online LUN
expansion is not require d or planned.)
Volume name a s seen on hostVolume on XP array (examples)
host mode = 0C host mode = 2C
OPEN-
E
OPEN-
E
OPEN-
E
OPEN-9 OPEN-9 OPEN-9
OPEN-9*2 OPEN-9*2 OPEN-9
OPEN
-9*3-CVS
OPEN
-9*3-CVS
OPEN
-9-CVS
CAUTION:
The correct host mode must be set for all new installations (newly connected ports) to Windows
2000
/2003 hosts. Do not select a mode other than 2C and 0C for Windows 2000/2003. Changing a
hos
t mode after the host has been connected is disruptive and requires the server to be rebooted.
HP StorageWorks Disk Array XP operating system conguration guide: Windows 2000/2003
13