user manual
Separation roller (Tray 2)
CAUTION: Do not touch the spongy roller surface unless you are replacing the roller. Skin oils on the
roller can cause paper pickup problems.
NOTE: Remove the Tray 2 cassette if not already removed for service. See Tray cassette on page 86.
Remove two screws (callout 1), and then remove the separation roller assembly (callout 2).
Figure 2-29 Remove the separation roller (Tray 2)
1
2
ENWW
Customer self repair (CSR) components
93