User's Manual
Table Of Contents
Microinverter user manual
14
Green light flashes slowly
(4s interval)
Microinverter works normally but
the communication with the DTU is
abnormal
Red light flashes
(1s interval)
Grid anomaly
Step 7. Energize the System
a. If applicable, turn on the AC disconnect or circuit breaker for the
branch circuit.
b. Turn on the main utility-grid AC circuit breaker. Your system will start
producing power after about a two-minute wait time.
Step 8. System Monitoring Set Up
Refer to the DTU User Manual or the DTU Quick Install Guide to install
the DTU and set up system monitoring.
4. TECHNICAL DATA
Model
MI-1000
Input data(DC)
Recommended input power (W)
4*200~310
MPPT voltage range (V)
27~48
Operating voltage range (V)
16~60
Maximum input voltage (V)
60
Maximum input current (A)
4*10.5
Maximum short circuit current limit (A)
4*15