Instruction Manual

Door Switch Contact Rd/Yl
EX204 Battery powered for use where a 4. OUT OF THE BOX factory default settings
separate supply of power is not available and are suitable for most applications. On first use
the protected door is opened infrequently or we recommend that you use these settings to
there is no requirement to sound the sounder test the EXITGUARD. They can be changed
for long periods. Can be powered from 12vdc if later to suit local requirements. Test by entering
necessary. (Discard batteries)
the user code and pressing I for Chime Mode.
A chime will be heard each time the door is
EX205 12vdc powered for use where the
opened.
protected door may be opened frequently or
Advanced Installation
the integral sounder needs to sound for
The following parameters can be changed
protracted periods. This version can also be
through the keypad:
interfaced with other equipment. There are volt
1. User Code
free relay contacts to separately signal
2. Select one of six different alarm tones
ON/OFF status and alarm conditions at remote
3. Change auto re-arm delay 0 - 88 secs
points. Cannot be powered from batteries.
4. Change Door Open Too Long (DOTL1)
EX206 230vac powered version where the
delay for keypad reset mode 0 secs - 88 mins.
protected door may be opened frequently or
5. Change DOTL2 delay for auto reset mode
the sounder needs to sound for protracted
0secs - 88mins.
periods. There is a volt free alarm relay contact.
6. Switch Bleep In Off (BIO) on or off.
This version is supplied with 6 x AA alkaline
7.Add or change a Reset/Pass Code
batteries for standby - Note: the batteries will
8. Add or change a Manager Code.
not power the alarm relay.
OUT OF THE BOX User Operation.
All versions have key pad control, integral
There are four possible modes:
sounder with programmable tones, 5 mode
Off Mode
LEDs, a front/back acting tamper switch and a
Chime Mode I
logic output to signal to a MULTIGUARD
Keypad Reset Mode II
indicator from HED. All are supplied with a door
Auto re-arm Mode III
contact, fixing screws and door warning label.
Quick Install
When the User Code is entered the
EXITGUARD is interrogated and one of the
EXITGUARDS are NOT intended for external
mode LEDs illuminates to indicate the current
use and to avoid damage should not be fixed to
status.
the protected door itself.
After the User Code is entered there is a 5sec
1.The door contact is in two parts; the magnet
window to change the mode, eg. If the current
should be fixed to the door and the contact with
mode is OFF and it is desired to switch to the
its cable fitted to the frame. The cable should
Keypad Reset mode just enter II ie 2 on the
be taken to the EXITGUARD and connected as
keypad. Within 5secs the LED will extinguish. If
shown. A is the alarm input for the switch
a mistake has been made this can be rectified
element (BL/YL) of the contact and T is from
before the LED extinguishes by simply
the tamper loop (RD/BK) of the contact.
selecting the desired mode, the LED indication
2. Make all connections, apply power, a double
will change to the new mode.
bleep will be heard and the four mode LEDs will
If the Auto re-arm mode is selected then the
illuminate.
factory default period of 30secs will be used
3. When the EXITGUARD leaves the factory
unless set up differently. (see programming
there are no codes in memory. The four
instructions to change the Auto re-arm period
illuminated red LEDs are inviting you to
and other functions)
enter a User Code. This must be a four digit
memorable code. As the code is entered
acknowledge bleeps are heard and each of
the mode LEDs will extinguish. The code is
now stored in memory and the EXITGUARD
will emit a double bleep and should be in the
OFF mode.
BK RD PP
HED
Door Switch tamper
loop Bl/Bk
These relay contacts
change state when the
EXITGUARDis armed.
EX205 only.
These relay contacts
change state when an
alarm condition is
generated.
EX205 & EX206
16vac
M
R
ve
+
ve
-
To
These terminals
are only used on
EX204 & EX206
If required the tamper switch To can be:
a. wired in series with the Red or Black door switch
tamper loop to give an audible alarm at any time.
b. wired in series with the Blue or Yellow of the door
switch contact pair to give an alarm condition only
when the Exitguard is armed.
c. wired to a remote device to give a warning at a
remote location.
d. ignored and not connected at all.
The on board tamper switch is
connected to these two terminals, To
If the tamper switch is required fit the spring
ensuring contact with the wall when the lid is fitted,
and operates when the lid is removed.
A
T
12vdc
EX204 Apply 12vdc (140ma max) here if required.
EX205 Apply 12vdc (165ma max) here.
EX206 12vdc available here @ 100ma max when mains power is available.
EXITGUARD EX200 series Installation Instructions
RELAY 1 RELAY 2
Input for Fire Door Checker (see scenario 4) Or Temporary Pass through (see scenario 7)
Apply 12vdc +ve to invoke Fire Door Checker. This can be
derived from an intruder, time clock or keyswitch etc..
Apply momentary 12vdc +ve for return pass through.
Factory Default.
To restore the factory default settings
disconnect power completely for about 10
secs. Ensure the door contact & tamper loop
are open. Move the SYSTEM RESET
jumper J1 from its normal position to the
reset position. Re-apply power four bleeps
will be heard. Replace the jumper to the
normal position. Two beeps will be heard
and the four mode LEDs should be
illuminated inviting you to enter a new user
code. Re-close the tamper & door contact..
The Factory default settings are as follows:
User Code None
Auto re-arm period 30 seconds
DOTL1 delay 00 seconds
DOTL2 delay 00 Seconds
Sounder Tone 1
I
II
III
Chime mode
Off
Keypad reset mode
Auto re-arm mode
exitguard
Mode
LEDs
Power LED
Setup LED
NO
COM
NC
NO
COM
NC
SYSTEM J1
RESET
{
Z1
Z2
Z3
Z4
Z5
Z6
F3
MULTIGUARD 2000 - 6
O/P to optional MULTIGUARD
Neutral
Earth
1 AM
P
230vac
Transformer is fitted in the enclosure back
box and is pre-wired to the circuit board.
EX206 Mains Powered Version Only
DWG No: 60112 Issue 2, Nov 2013
1
4 5 6
7 8 0
2
3
II IIII IIIIII
Keypad
T. 01744 886600 F. 01744 886607 E. sales@hoyles.com W. www.hoyles.com
Hoyles Electronic Developments Ltd
NORM
RESET
8mm (max gap)
Magnetic Door Contact.
Fit to door frame and
protect from moisture
Magnet. Fit to door
& align with contact

Summary of content (2 pages)