User's Manual
35
Enable:Press【Enter】 select: ON/MOVE/OCC.
Limit: Set the threshold of video area/detection area percentage . Suggest 65.
Sense: Sensitivity , it decides the detection sensitivity level .Press【Enter】 to select: 1-8.
1 is the highest level. Suggest to use 3.
Record: Turn on/off recording function.Press【Enter】to select: On / Off.
Alarm linkage: Press【Enter】to select: OFF/Output 1 / Output 2 / Buzzer/snap-up.
Delay:Linkage‟s duration time. Press number keys to set.
Attention:
1.Regarding the occlusion/motion detect function. we suggest choose 4 channels at most.
2 After you set the parameter, please restart the device.
9.2.5.5. Voltage alarm
If the operation voltage is low, it will trigger the alarm. The system can work at 8-36V (The lower voltage,
the more current demanding), it‟s better work at 12/24V. So you can set a Limit value first.










