User guide

Optional Features and Accessories
The following optional features and accessories are avail-
able. Check with the factory for the availability of other
features and accessories not listed.
Series-multiple high-voltage winding
Delta-wye connection
Special high-voltage taps
Special low-loss high efciency designs
Design optimization to lowest total owning cost
50 Hertz operating frequency
Special impedance
Special sound level
Special phase relationship
Special BIL level
Over excitation capability
65° C average temperature rise
Special ambient temperature
Operation at altitudes above 3300 feet
Copper windings
Core ground test point located inside tank accessible
from bolted handhole
Electrostatic shields
Optional tank features and accessories
Special hardware
Welded handhole cover
Additional bolted or welded hand-hole
Special tank design pressure (up to 15 psig)
Ground connectors
Special tank dimensions
Tank undercoating
Omit pressure-relief valve
Optional gauges and ttings
Dial-type magnetic liquid-level gauge (with alarm
contacts)
Dial-type thermometer (with alarm contacts)
Pressure-vacuum gauge (with or without alarm
contacts)
Automatic pressure-relief device (with or without
alarm contacts)
Drain valve with liquid sampling valve
Additional drain valve on tank or switch chamber
Spare gaskets for secondary throat, bolted hand-
holes, high-voltage terminal chamber, and switch
chamber
Sight gauge for high-voltage terminal chamber
Other options (check with factory)
Optional high-voltage switch features and accessories
Interrupting switch or other special switches
Provisions for phase sequence identication
(phasing tubes)
Phase sequence indication (sequential ground-
ing), including 3 internal grounding contacts,
5-position switch to indicate phase when switch is
moved from transformer positions to ground posi-
tion
Additional electrical interlocks
Viewing windows for observation of switch blades
(with hinged protective cover)
Optional high-voltage entrance features and accessories
Single-conductor or multi-conductor wiping
sleeves, or pothead entrance
Six universal bushing wells for loop feed with or
without loadbreak inserts (HV switch must be
omitted)
Three integral loadbreak bushings
Three non-Ioadbreak bushings
Six non-Ioadbreak bushings for loop feed (HV
switch must be omitted)
Six integral loadbreak bushings for loop feed (HV
switch must be omitted)
Three molded bushings mounted on front of
terminal chamber in lieu of the standard wiping
sleeve
Potheads, one 3-conductor or three 1-conductor,
instead of the standard terminal chamber
Bottom entrance of HV cable, including wiping
sleeves
Packing gland or stufng box
Phase separation barriers in compartment (when
switch is omitted)
Dielectric uid or compound for terminal chamber
Optional low-voltage air terminations
Welded low-voltage bushings
Fully insulated low-voltage neutral bushing
Other low-voltage termination options (check with
factory)
Optional network protector provisions (check with factory)
Optional dielectric uids
Silicone uid
FR3 natural ester-based uid
Network Transformer94-10
Copyright © 2010 Howard Industries, Inc.
6
Howard Industries, Inc.
Laurel, MS 39440
www.howardtransformers.com
Catalog Section 94-10
Network Transformers
Issued: April 9, 2010