Owner manual

TROUBLESHOOTING
34 TOUCH USER MANUAL
Error Code Problem Possible solution
12 SSR too hot The solid-state relay is too hot. Clean
the inlet lter at the bottom of the
panel. Contact authorized service
personnel.
13 Generator too hot The temperature of the steam generator
is higher than 130°C. If the error recurs,
contact authorized personnel to descale.
14 Fan running too slow Check inlet lter at the bottom of
the panel. If the error recurs, contact
authorized service personnel.
16 IO board too hot Contact authorized service personnel.
19 Internal defect An internal software error occurred.
Restart the oven.
20 Internal defect A communication failure occurred
between the computer and the IO
board. Contact authorized service
personnel.
21 Invalid program You have chosen a program that is not
supported by the oven.
22 Programme interrupted A program in progress was interrupted
because of a power supply interruption.
The power supply interruption lasted
so long that the program cannot be
restarted.
24 Draining failure The steam generator could not be
emptied during ushing. The level
sensor reports high water level when
the generator is emptied. Contact
authorized service personnel.
25 ClimaOptima The ClimaOptima function has not been
calibrated. Go to the service menu to
calibrate.