User Manual
USER MENU
22 COMBISLIM USER MANUAL C
Value Function Description
6 Interior light Press STEP: 0 = continuously on / 5 = o after 5 min. /
1 (B model) = continuously on but o when door open
/ 6 = o after 5 min. but o while door open.
7 Current
temperature
0 = desired temperature / 1 = current temperature.
Adjust by pressing STEP.
8 Extraction Applicable only if oven has condensing extraction
hood. 0 = extraction hood running independently of
oven / 1 = extraction hood stops 10 minutes after oven
has stopped.
9 Time graphics Shown in text display during operation. Change by
pressing STEP.
0 = Display shows mode chosen
1 = Display alternately shows mode chosen and time
remaining.
10 Minutes Minutes are shown in temperature display. Change by
pressing temperature key and turning knob. Store by
pressing temperature key again.
11 Hour Hour is shown in temperature display. See 10.
12 Day Day of the month, 1-31. Day of the week, 1 – 7, in
time display. See 10.
In Europe, you can choose to have the computer
switch to summer time automatically. 0 = No change, 1
= Change from/to summer time.
13 Month Month. See 10.
14 Year The year 2007 is indicated by ”7”. See 10.
16 Cook & Regen Setting of humidity pulsing. Press temperature key and
turn knob to change setting. The value indicates the
number of seconds between each injection into the
oven chamber. If the value is increased, less humidity
is added to the oven chamber, if the value is reduced,
more humidity is added (factory setting is every 8
seconds).
17