User's Manual

31
HBM: Business Document
12 Specifications
Ty
pe
TCA MPZ1605016
Accuracy class
0.3
Torque measuring system
Nominal (rated) torque M
nom
kN·m
30
Nominal (rated) sensitivity
(spread between torque =
zero and nominal (rated) torque)
Freq. output 10 kHz
Voltage output
Sensitivity tolerance
(deviation of the actual output
quantity at M
nom
from the nominal (rated) sensitivity)
All outputs
kHz
V
%
5
10
<±0.3
Output signal
at
torque
=
zero
Frequency output
Voltage output
kHz
V
10
0
Nominal output signal
Frequency output
at positive nominal (rated) torque
at negative nominal (rated) torque
Voltage output
at positive nominal (rated) torque
at negative nominal (rated) torque
kHz
kHz
V
V
15 (TTL)
5 (TTL)
+10
-10
Low-pass filter
Low-pass filter LP1
Low-pass filter LP2
Hz
Hz
100
1000
Measurement frequency range,
-3
dB
Hz
0 … 1000
Temperature influence
per 10 K
in the
nominal
temperature range
on the
output signal,
related to
the
actual value of the
signal span (TKC)
Frequency output
Voltage output
on the
zero signal,
related to the
nominal (rated)
sensitivity (TK0)
Frequency output
Voltage output
%
%
%
%
<±0.1
<±0.1
<±0.1
<±0.1
Maximum
level control range
Frequency output
Voltage output
kHz
V
4.5 ... 15.5
-11 … +11
Energy supply
Nominal (rated) supply voltage (separated extra low
DC voltage)
Maximum power consumption
Maximum cable length
V
W
m
9 - 36
30
50