User's Manual

Table Of Contents
Mechanical installation
T40B A3452-10.0 27
without rotational speed
measuring system
with rotational
speed measuring
system
Flange plane faces
Transmitter winding
Rotational speed measuring system
Measuring
zone
Fig. 5.1 Bolted rotor connection
1. Prior to installation, clean the plane faces of the trans
ducer flange and the counter flange.
For safe torque transfer, the faces must be clean and
free from grease. Use a piece of cloth or paper
soaked in solvent. When cleaning, make sure that you
do not damage the transmitter winding or the rota
tional speed measuring system.
2. For the bolted rotor connection (see Fig. 5.1), use six
or eight DIN EN ISO 4762 hexagon socket screws of
the property class stated in Tab. 5.1, in a suitable
length (dependent on the connection geometry, see
Tab. 5.1 on page 29).
We recommend DIN EN ISO 4762 socket head cap
screws, blackened, smooth‐headed, permitted size
and shape variance in accordance with DIN
ISO 4759, Part 1, product class A.