User's Manual
Table Of Contents
- T40FH
- T40FH
- English
- 1 Safety instructions
- 2 Markings used
- 3 Application
- 4 Structure and mode of operation
- 5 Mechanical installation
- 6 Electrical connection
- 7 TEDS transducer identification (Option 3, Code PNJ)
- 8 Shunt signal
- 9 Functionality testing
- 10 Load-carrying capacity
- 11 Maintenance
- 12 Waste disposal and environmental protection
- 13 Dimensions
- 14 Ordering numbers, accessories
- 15 Specifications
- 16 Supplementary technical information
- English
- T40FH
- Deutsch
- 1 Sicherheitshinweise
- 2 Verwendete Kennzeichnungen
- 3 Anwendung
- 4 Aufbau und Wirkungsweise
- 5 Mechanischer Einbau
- 6 Elektrischer Anschluss
- 7 Aufnehmer‐Identifikation TEDS (Option 3, Code PNJ)
- 8 Shuntsignal
- 9 Funktionsprüfung
- 10 Belastbarkeit
- 11 Wartung
- 12 Entsorgung und Umweltschutz
- 13 Abmessungen
- 14 Bestellnummern, Zubehör
- 15 Technische Daten
- 16 Ergänzende technische Informationen
- Deutsch
Functionality testing
52 A4429-1.0 HBM: public T40FH
9.1 Rotor status, LED A (upper LED)
Color Significance
Green (pulsating) Internal rotor voltage values o.k.
Flashing orange Rotor and stator mismatched (an increasing flashing fre
quency indicates the degree of misalignment)
=> Correct the rotor/stator alignment.
Pulsating orange Rotor status cannot be defined
=> Correct the rotor/stator alignment.
If the LED still pulsates orange, it is possible that there is a
hardware defect. The measurement signals reflect the level of
the fault.
Red (pulsating) Rotor voltage values not o.k.
=> Correct the rotor/stator alignment.
If the LED still pulsates red, it is possible that there is a hard
ware defect. The measurement signals reflect the level of the
fault.
Pulsating means that the LED goes dark for about 20 ms
every second (sign of life), making it possible to detect
that the transducer is functioning.
9.2 Stator status, LED B (lower LED)
Color Significance
Green
(permanently lit)
Measurement signal transmission and internal stator voltages
o.k.
Green, intermittently
orange.
Numerous synchro
nization errors:
permanently orange
Orange if y5 measured values in succession are transmitted
incorrectly, until the end of incorrect transmission. The mea
surement signals reflect the level of the fault for the duration
of the transmission error + for approx. another 3.3 ms.