User's Manual
Table Of Contents
- T40FH
- T40FH
- English
- 1 Safety instructions
- 2 Markings used
- 3 Application
- 4 Structure and mode of operation
- 5 Mechanical installation
- 6 Electrical connection
- 7 TEDS transducer identification (Option 3, Code PNJ)
- 8 Shunt signal
- 9 Functionality testing
- 10 Load-carrying capacity
- 11 Maintenance
- 12 Waste disposal and environmental protection
- 13 Dimensions
- 14 Ordering numbers, accessories
- 15 Specifications
- 16 Supplementary technical information
- English
- T40FH
- Deutsch
- 1 Sicherheitshinweise
- 2 Verwendete Kennzeichnungen
- 3 Anwendung
- 4 Aufbau und Wirkungsweise
- 5 Mechanischer Einbau
- 6 Elektrischer Anschluss
- 7 Aufnehmer‐Identifikation TEDS (Option 3, Code PNJ)
- 8 Shuntsignal
- 9 Funktionsprüfung
- 10 Belastbarkeit
- 11 Wartung
- 12 Entsorgung und Umweltschutz
- 13 Abmessungen
- 14 Bestellnummern, Zubehör
- 15 Technische Daten
- 16 Ergänzende technische Informationen
- Deutsch
Electrical connection
42 A4429-1.0 HBM: public T40FH
Assignment for connector 4
TMC - only for connection to the Torque Interface Mod
ules of the TIM family within HBM.
6.4 Connector pin assignment Option 3,
Code PNJ
61
5
72
4
3
Binder 723
Top view
Con
nector
pin
Assignment Color
code
1 Measurement signal (+) UA wh
2 Bridge excitation voltage (-) UB and
TEDS
bk
3 Bridge excitation voltage (+) UB bu
4 Measurement signal (-) UA rd
5 Not in use -
6
Sense lead (+)
gn
7
Sense lead (-) and TEDS
gy
Shield connected to housing ground
6.5 Supply voltage (SU2, DU2, HU2)
The transducer must be operated with a safety extra-low
voltage (nominal (rated) supply voltage 18 … 30 V
DC)
.
You can supply one or more torque flanges within a test
bench. Should the device be operated on a DC voltage
network
1)
, additional precautions must be taken to dis
charge excess voltages.
1)
Distribution system for electrical energy with greater physical expansion (over several test
benches, for example) that may possibly also supply consumers with high nominal (rated)
currents.