User's Manual

Table Of Contents
Electrical connection
T40FH A4429-1.0 HBM: public 39
Notice
Torque flanges are only intended for operation with a DC
supply voltage. They must not be connected to older
HBM amplifiers with square-wave excitation. This could
destroy the connection board resistors or cause other
faults in the amplifiers.
Assignment for connector 2 - rotational speed
measuring system
6
1
5
7
2
4
3
8
Device plug
Top view
KAB154 KAB150 KAB179
1)
Con
nector
pin
Assignment Color
code
D-SUB
connec
tor
pin
HD-SUB
connec
tor
pin
1
Speed measurement signal
2)
(pulse
string, 5V; 0°)
rd 12 10
2 Not in use bu - -
3
Speed measurement signal
2
(pulse
string, 5 V; 90° phase shifted)
gy 15 8
4 Not in use bk - -
5 Not in use vt - -
6
Speed measurement signal
2)
(pulse string, 5V; 0°)
wh 13 5