14
Specifications
Ty
pe
MPZ1006008-12 / MPZ1006009-12
Accuracy class
0.1
Torque measuring system
Nominal (rated) torque M
nom
kN⋅m
15
25
Nominal (rated) sensitivity
(spread between torque =
zero and nominal (rated) torque)
Freq. output 10 kHz / 60 kHz / 240 kHz
Voltage output
Sensitivity tolerance
(deviation of the actual output
quantity at M
nom
from the nominal (rated) sensitivity)
Voltage output
kHz
V
%
30
10
±
0.1
Output signal
at
torque
=
zero
Frequency output
Voltage output
kHz
V
60
0
Nominal output signal
Frequency output
at positive nominal (rated) torque
at negative nominal (rated) torque
Voltage output
at positive nominal (rated) torque
at negative nominal (rated) torque
kHz
kHz
V
V
90
2)
(5 V symmetrical
4)
)
30
2)
(5 V symmetrical
4)
)
+10
-10
Load resistance
Frequency output
Voltage output
Long-term drift
over 48
h
Frequency output
Voltage output
kΩ
kΩ
%
%
≥ 2
≥10
<
±
0.03
<
±
0.03
Measurement frequency range,
-3
dB
kHz
3
2)
Group delay
µs
<
220
2)
Residual ripple
Voltage output
5)
mV
<
40
Temperature influence
per 10 K
in the
nominal
temperature range
on the
output signal,
related to
the
actual value of the
signal span
Frequency output
Voltage output
on the
zero signal,
related to the
nominal (rated)
sensitivity
Frequency output
Voltage output
%
%
%
%
±
0.05
±
0.2
±
0.05
±
0.1