User's Manual

15
5.5
Mounting the rotor
T
ip
Usually the rotor identification plate is no longer visible after installation. This is why we
include with the rotor additional stickers with the important ratings, which you can attach to
the stator or any other relevant test-bench components. You can then refer to them
whenever there is anything you wish to know, such as the shunt signal.
1. Prior to installation, clean the plane surfaces of the transducer flange and the counter
flange.
For safe torque transfer, the surfaces must be clean and free from grease. Use a piece
of cloth or paper soaked in solvent. When cleaning, make sure that you do not damage
the transmitter winding
or the speed measuring system.
Transmitter winding
Speed measuring system
without speed
measuring
system
Flange plane
faces
with speed
measuring system
Fig. 5.9: Bolted rotor connection
Version b 13.01.2015 HBM: public