Installation Instructions and Manual
4 49-5000041 Rev. 3
USING THE AIR CONDITIONER
Controls
ŶPOWER
3UHVVWKH32:(5EXWWRQWRWXUQWKHXQLWRQRURII
:KHQWKHXQLWLVRQWKHSRZHULQGLFDWRUOLJKWZLOOEH
JUHHQ:KHQWKHXQLWLVRIIWKHOLJKWZLOOJRRXW
ŶMODE
3XVKWKLVEXWWRQWRF\FOHWKURXJKWKHPRGHVIURP
&22/+($7)$1&22/7KHLQGLFDWRUOLJKWEHVLGH
WKH³02'(´RSWLRQZLOOLOOXPLQDWHLGHQWLI\LQJWKH
mode selected.
&22/7KHUDQJHRIVHWWHPSHUDWXUHLV)a)
Cooling begins automatically when the room
temperature is above the set point,and stops when
WKHURRPWHPSHUDWXUHLV)EHORZWKHVHWSRLQW%XW
WKHFRPSUHVVRUZLOOUXQPLQXWHVDWOHDVWLQ&22/
mode before stopping. The fan runs in continuous
mode.
+($77KHUDQJHRIVHWWHPSHUDWXUHLV)a)
For heat pump models the unit can alternate running
between reverse cycle heat mode and electric heater
mode according to the difference between the set
temperature and the room temperature. The fan
motor cycles on and off with the compressor and
electric heater.
NOTE: Reverse cycle heating and electric heater
cannot be run at the same time. In the following
cases, it is normal that the compressor does not
operate.
:KHQWKHRXWGRRUWHPSHUDWXUHLVORZHUWKDQ)
RUWKHURRPWHPSHUDWXUHIDOOVWR)EHORZWKHVHW
point temperature.
2. There is a 3-minute minimum compressor run time
at any setting to prevent short cycling. The indoor
fan motors starts before the compressor and stops
after the compressor cycles off.
:KHQIURVWEXLOGVXSWRWKHHYDSRUDWRUFRLOVWKH
unit will defrost automatically and the compressor
will cycle off.
)$1)DQRSHUDWLRQRQO\ZLWKRXWKHDWLQJDQGFRROLQJ
NOTE: The set temperature ranges can be changed.
6HH³',36:,7&+(6&21),*85$7,216RQSDJH
for details.
ŶUP/DOWN BUTTONS ( + / - )
3XVKWKH83RU'2:1EXWWRQWRLQFUHDVHRU
decrease) the set temperature of the unit in cooling
or heating mode. The temperature can be set by
LQFUHPHQWVRI)7KHVHWWHPSHUDWXUHDSSHDUVLQ
the display.
NOTE: 3UHVVDQGKROGDQGEXWWRQVWRJHWKHUIRU
3 seconds will alternate the temperature display
EHWZHHQ&)VFDOH
ŶFAN (FAN SPEED)
(YHU\WLPH\RXSXVKWKLVEXWWRQWKHIDQVSHHGF\FOHV
WKURXJKWKHVHWWLQJVDVIROORZV+,*+0('/2:
Ŷ',63/$<6
:KLOHRQ)DQRQO\PRGHLWVKRZVWKHURRP
temperature.
Control code (on some models):
LC 3DGVRQWKHFRQWUROSDQHOLVQRWDYDLODEOH7KH
unit can be operated by using wall thermostat only.
)&3DGVRQWKHFRQWUROSDQHODQGZDOOWKHUPRVWDW
are not available. The unit can be operated by using
)5217'(6.&21752/RQO\
Error codes:
AS-Room temperature sensor error;
ES(YDSRUDWRUWHPSHUDWXUHVHQVRUHUURU
CS-Condenser temperature sensor error;
OS-Outside temperature sensor error;
HS([KDXVWWHPSHUDWXUHVHQVRUHUURU
LE:LUHFRWUROOHUHUURU
NOTE: :KHQHUURURFFXUVXQSOXJWKHXQLWDQGSOXJLW
back in.If error repeats, call for service.
2WKHUFRGHV
LO5RRPWHPSHUDWXUHLVORZHUWKDQ)
HI5RRPWHPSHUDWXUHLVKLJKHUWKDQ)
FP/RZWHPSHUDWXUHSURWHFWLRQ
NOTE:$OOWKHLOOXVWUDWLRQVLQWKLVPDQXDODUHIRU
explanation purpos only. Your air conditioner may be
slightly different. The actual shape shall prevail.
NOTE: This air conditioner is designed to be
RSHUDWHGXQGHUFRQGLWLRQDVIROORZV
NOTE:3HUIRUPDQFHPD\EHUHGXFHGLIRXWVLGHWKHVH
operating temperatures.
ÛC
Û)
+
-
Fan
Mode
Power
Cool
Heat
Fan
High
Med
Low
Air Conditioner Controls
Cooling Operation
2XWGRRU7HPS )
,QGRRU7HPS )
+HDWLQJ2SHUDWLRQ
2XWGRRU7HPS )
,QGRRU7HPS )