User's Manual
Table Of Contents
- CONTENTS
- I. Specifications
- 1. Icemaker
- KM-1300SAH
- KM-1300SWH
- KM-1300SRH
- KM-1300SAH3
- KM-1300SWH3
- KM-1300SRH3
- 2. Condensing Unit
- URC-12F
- II. General Information
- 1. Construction
- [a] KM-1300SAH, KM-1300SAH3
- [b] KM-1300SWH, KM-1300SWH3
- [c] KM-1300SRH, KM-1300SRH3
- 2. Controller Board
- [a] Solid-State Control
- [b] Controller Board
- [c] Sequence
- [d] Controls and Adjustments
- [e] Checking the Controller Board
- III. Technical Information
- 1. Water Circuit and Refrigerant Circuit
- [a] KM-1300SAH, KM-1300SAH3
- [b] KM-1300SWH, KM-1300SWH3
- [c] KM-1300SRH, KM-1300SRH3
- 2. Wiring Diagrams
- [a] KM-1300SAH, KM-1300SWH
- [b] KM-1300SRH
- [c] KM-1300SAH3, KM-1300SWH3
- [d] KM-1300SRH3
- 3. Timing Chart
- 4. Performance Data
- [a] KM-1300SAH
- [b] KM-1300SWH
- [c] KM-1300SRH
- [d] KM-1300SAH3
- [e] KM-1300SWH3
- [f] KM-1300SRH3
- IV. Service Diagnosis
- 1. No Ice Production
- 2. Evaporator is Frozen Up
- 3. Low Ice Production
- 4. Abnormal Ice
- 5. Other
- V. Removal and Replacement of Components
- 1. Service for Refrigerant Lines
- [a] Refrigerant Recovery
- [b] Evacuation and Recharge [R-404A]
- 2. Brazing
- 3. Removal and Replacement of Compressor
- 4. Removal and Replacement of Drier
- 5. Removal and Replacement of Expansion Valve
- 6. Removal and Replacement of Hot Gas Valve and Line Valve
- 7. Removal and Replacement of Evaporator
- 8. Removal and Replacement of Water Regulating Valve - Water-Cooled Model Only
- 9. Adjustment of Water Regulating Valve - Water-Cooled Model Only
- 10. Removal and Replacement of Condensing Pressure Regulator (C.P.R.) -
- 11. Removal and Replacement of Thermistor
- 12. Removal and Replacement of Fan Motor
- 13. Removal and Replacement of Water Valve
- 14. Removal and Replacement of Pump Motor
- 15. Removal and Replacement of Spray Tubes
- VI. Maintenance and Cleaning Instructions
- 1. Preparing the Icemaker for Long Storage
- 2. Cleaning and Sanitizing Procedures
- [a] Cleaning Procedure
- [b] Sanitizing Procedure - Following Cleaning Procedure
- 3. Maintenance

43
IV. Service Diagnosis
1. No Ice Production
Problem Possible Cause Remedy
[1] a) Power Supply 1. OFF position. 1. Move to ON position.
2. Loose connection. 2. Tighten.
3. Bad contacts. 3. Check for continuity and
replace.
4. Voltage too high. 4. Check and get
recommended voltage.
b) Fuse (Inside fused
disconnect, if any)
1. Blown. 1. Check for short circuit and
replace.
c) Control Switch 1. OFF position. 1. Move to ICE position.
2. Bad contacts. 2. Check for continuity and
replace.
d) Bin Control Thermostat 1. Tripped with bin filled with
ice.
1. Remove ice.
2. Ambient temperature too
cool.
2. Increase ambient
temperature.
3. Set too warm. 3. See "II.2.[d] Controls and
Adjustments, 6) Bin
Control."
4. Bulb out of position. 4. Place in position.
5. Bad contacts or leaks in
bulb.
5. Check for continuity and
replace.
e) High Pressure Control 1. Bad contacts. 1. Check for continuity and
replace.
f) Transformer 1. Thermal fuse blown or coil
winding opened.
1. Replace.
g) Wiring to Controller
Board
1. Loose connections or
open.
1. Check for continuity and
replace.
h) Thermistor 1. Leads short-circuit or open
and high temperature
safety operates.
1. See "II.2.[d] Controls and
Adjustments, 1) Defrost
Control."
i) Hot Gas Solenoid
Valve
1. Continues to open in
freeze cycle and high
temperature safety
operates.
1. Check for power off in
freeze cycle and replace.
The icemaker will not
start.