B. Defrost
There are 2 types of defrost: Off Cycle Defrost and Heated Defrost.
Manual Initiation (All Models): Turn the TD all the way to the right. Wait 3 sec. then
back to original setting. Defrost initiated.
Refrigerator Off Cycle Defrost Automatic Initiation: Compressor cycles off with
cabinet setpoint temperature achieved.
Heated Defrost Automatic Initiation: Temperature achieved and defrost timer
terminates.
Manual Termination: Turn the TD all the way to the right. Wait 3 sec. then back to
original setting. Defrost terminated.
Automatic Termination: Cabinet temperature above setpoint, or defrost thermistor
above termination temperature, or backup defrost timer terminates.
1. Undercounter and Worktop Refrigerators
Off-Cycle Defrost: Undercounter and worktop refrigerators defrost naturally between run
cycles.
III. Controls and Adjustments
A. Temperature Settings
1. Temperature Reading
A thermometer with both °F and °C scales is mounted in the cabinet. See Fig. 1.
2. Cabinet Temperature
The appliance features a cabinet temperature control dial (TD). The warmest setting
is 1and the coldest setting is 7. See the table for default cabinet temperature control
settings.
Model Default Cabinet Temperature
Control Setting
Approximate Default Temperature
Undercounter
Worktop
Between 4 and 5 Refrigerator: 34°F (1°C)
Freezer: -5°F (-21°C)
Prep Table Between 4 and 5 34°F (1°C)
Fig. 1
Thermometer
Cabinet Temperature
Control Dial
Warmer Colder