g) Alarm Safeties
LEDS Mains Voltage Compressor Description
R Y G on on
Off.Voltage bad (too high or too low).
Wait period. (Intelligent Time Delay).
Allows neutralisation of refrigerant pressure.
On. Voltage good. No wait time. Cooling demand.
Defrost Period. Starts after 4 hours of accumulated compressor
run time for 25 minutes.
No cool demand (NCD). Voltage is bad.
No cool demand (NCD). Wait is on.
No cool demand (NCD). In cut-out zone.
Test mode. If in the No cool demand (NCD), this forces
compressor to go on for 10 seconds.
Probe fault. Normally compressor shuts down unless speci ed by
customer to cycle with pre-determined time sequence.
Fault. Mains sense auto recovery possible.
Knob in off position.
KEY On/good Off/bad Not relevant Flashing Cycling Off On