Service Manual

Table Of Contents
9. Remove the screws that hold in place the
relay to the electrical box using a
screwdriver # 2.
DISCONNECT UNIT FROM POWER SUPPLY BEFORE DOING ANY SERVICE
Instruction to Replace Starting Relay, Overload Protector and Starting Capacitor.
10. Use a slotted screwdriver as a pry bar
to pull out the electrical connectors
from the relay .
11. To install the new relay reverse the
previous steps.