Compressor will not 1. Power disconnected 1. Check cord for proper
start, no noise connecon
2. Blown fuse or 2. Replace fuse or
breaker reset breaker
3. Defecve or broken 3. Repair or replace
wiring
4. Defecve overload 4. Replace
5. Defecve relay 5. Replace
Warm storage 1. Defecve control 1. Replace
temperatures 2. Not enough 2. Leak check. Change
refrigerant drier, evacuate and
recharge
3. Cabinet locaon too 3. Relocate cabinet
warm
4. Too much refrigerant 4. Change drier,
evacuate and recharge
5. Low voltage, com- 5. Check voltage
pressor cycling on supply
overload
Compressor runs con- 1. Defecve control 1. Replace
nuously-product too 2. Control’s sensor 2. Reposion control sensor
cold out of its bracket into its bracket
3. Not enough 3. Leak check. Change
refrigerant drier, evacuate and
recharge
Compressor runs 1. Not enough 1. Leak check. Change
connuously-product refrigerant drier, evacuate and
too warm recharge
2. Inecient compressor 2. Replace
TROUBLESHOOTING CHART