Instruction Manual

19
Compressor will not 1. Power disconnected 1. Check cord for proper
start, no noise connecon
2. Blown fuse or 2. Replace fuse or
breaker reset breaker
3. Defecve or broken 3. Repair or replace
wiring
4. Defecve overload 4. Replace
5. Defecve relay 5. Replace
Warm storage 1. Defecve control 1. Replace
temperatures 2. Not enough 2. Leak check. Change
refrigerant drier, evacuate and
recharge
3. Cabinet locaon too 3. Relocate cabinet
warm
4. Too much refrigerant 4. Change drier,
evacuate and recharge
5. Low voltage, com- 5. Check voltage
pressor cycling on supply
overload
Compressor runs con- 1. Defecve control 1. Replace
nuously-product too 2. Control’s sensor 2. Reposion control sensor
cold out of its bracket into its bracket
3. Not enough 3. Leak check. Change
refrigerant drier, evacuate and
recharge
Compressor runs 1. Not enough 1. Leak check. Change
connuously-product refrigerant drier, evacuate and
too warm recharge
2. Inecient compressor 2. Replace
TROUBLESHOOTING CHART